Failed to Configure Static Binding Entries and Dynamic Binding Function
Symptom
Configuring static binding entries and dynamic binding function fails on a port.
Analysis
IP Source Guard is not supported on the port which has joined an aggregation group. Neither static
binding entries nor dynamic binding function can be configured on the port which has joined an
aggregation group.
Solution
Remove the port from the aggregation group.