Checklist before installation
Table 5 Checklist before installation
Item Re
q
uirements
Result
Installation
site
Ventilation
There is a minimum clearance of 10 cm (3.94 in) around
the inlet and outlet air vents for heat dissipation of the
firewall chassis.
A ventilation system is available at the installation site.
Temperature
Operating: 0°C to 40°C (32°F to 104°F)
Non operating: –40°C to +70°C (–40°F to +158°F)
Relative humidity
Operating: 10% to 95% (noncondensing)
Non operating: 5% to 95% (noncondensing)
Cleanness
Dust concentration 3 × 10
4
particles/m
3
No dust on desk within three days
ESD prevention
The equipment and rack are well grounded.
The equipment room is dust-proof.
The humidity and temperature are at a proper level.
Wear an ESD-preventive wrist strap and make sure the
wrist strap makes good skin contact and is well
grounded when installing FRUs.
Put cards away on an ESD-preventive workbench, with
the PCB upward, or put them in ESD-preventive bags for
future use.
Touch only the edges, instead of electronic components
when observing or moving a removed interface card.
EMI prevention
Take effective measures to protect the power system from
the power grid system.
Separate the protection ground of the firewall from the
grounding device or lightning protection grounding
device as far as possible.
Keep the firewall far away from radio stations, radar and
high-frequency devices working in high current.
Use electromagnetic shielding when necessary.