5. Use a needle-nose pliers to bend a hook at the other end of the grounding cable, attach it to the
grounding point, and secure it with a screw.
Figure 9 Connecting the grounding cable to the grounding point on the rack
Grounding the firewall with a grounding strip
If a grounding strip is available at the installation site, connect the grounding cable through the
grounding strip.
To connect the grounding cable:
1. Remove the grounding screw from the firewall chassis.
2. Attach the grounding screw to the ring terminal of the grounding cable.
3. Use a Phillips screwdriver to fasten the grounding screw into the grounding screw hole.
4. Remove the hex nut from the grounding strip.
5. Use a needle-nose pliers to bend a hook at the other end of the grounding cable, attach it to the
grounding point, and secure it with a screw.