51
Appendix B FRUs and compatibility matrixes
MPUs
MPU is the core of the control management plane for the M9000 gateway series. The MPU model
available for the M9000 gateway series is NSQ1SUPB0.
An M9000 gateway requires one MPU to operate correctly. You can install one MPU, or two MPUs for
redundancy
Table 16 MPU specifications
Item Description
Interfaces
One console port for local or remote dialup configuration management
One 10/100/1000BASE-T Ethernet interface for management and upgrade
Interface transmission
rate
Console port—No greater than 115200 bps and defaults to 9600 bps
10/100/1000BASE-T interface—10/100/1000 Mbps
Cables and max
transmission distance
Console port—15 m (49.21 ft) over common asynchronous serial interface cable
10/100/1000BASE-T interface—100 m (328.08 ft) over Category-5 twisted
pairs
For more information about the NSQ1SUPB0, see H3C SecPath M9000 NSQ1SUPB0 MPU Card
Manual.
Service modules
The services modules available for the M9000 security gateway are described in Table 17.
Table 17 Service module specifications
Model Descri
p
tion Interface
Connector
NSQ1FWCEA0
Firewall service
module
1 console port RJ-45
2 Gigabit combo interfaces. Each combo
interface includes:
One 10/100/1000BASE-T copper port
One 1000BASE-X SFP fiber port
RJ-45
LC
For more information about the service modules, see the card manuals that come with the service
modules.
LPUs
The LPUs available for the M9000 gateway series are described in Table 18.
Vista de pagina 58