H3c-technologies H3C SecPath F1000-E Manual de usuario

Busca en linea o descarga Manual de usuario para La Seguridad H3c-technologies H3C SecPath F1000-E. H3C Technologies H3C SecPath F1000-E User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 95
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
H3C SecPath F1000-E/F1000-S-EI Firewalls
Installation Guide
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: T2-080498-20130830-C-1.08
Vista de pagina 0
1 2 3 4 5 6 ... 94 95

Indice de contenidos

Pagina 1 - Installation Guide

H3C SecPath F1000-E/F1000-S-EI FirewallsInstallation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document vers

Pagina 2

2 F1000-S-EI chassis views Figure 3 F1000-S-EI front view (1) Copper Ethernet ports 0 to 5 (10/100/1000Base-T) (2) Console port (CONSOLE) (3) USB por

Pagina 3 - Preface

3 Figure 5 4GBE panel view (1) Captive screw (2) Copper Ethernet ports (GE 0 to GE 3) (3) Ejector lever Figure 6 8GBE panel view (1) Captive scre

Pagina 4 - Port numbering in examples

4 4GBP The 4GBP interface module provides four fiber SFP Ethernet ports, which can be set to operate as Layer 3 interfaces or Layer 2 interfaces. Conn

Pagina 5 - Documentation feedback

5 Figure 10 NSQ1GP4U0 panel view (1) Captive screw (2) SFP fiber ports (SFP 0 to SFP 3) (3) Ejector lever Interface module and chassis compatibility

Pagina 6 - Contents

6 Preparing for installation Safety recommendations To avoid possible bodily injury and equipment damage, read all safety recommendations carefully be

Pagina 7

7 WARNING! • Do not stare into any fiber port when the firewall has power. The laser light emitted from the optical fiber may hurt your eyes. • Use

Pagina 8

8 Item Temperature Storage temperature –40°C to +70°C (–40°F to +158°F) Table 2 Humidity requirements Item Relative humidity Operating humidity 10%

Pagina 9 - Product overview

9 Figure 11 Airflow through the chassis (F1000-E) ESD prevention CAUTION: • Check the resistance of the ESD-preventive wrist strap for safety. Th

Pagina 10 - Interface modules

10 Figure 12 Attaching an ESD-preventive wrist strap (1) Alligator clip (2) Lock (3) ESD-preventive wrist strap EMI All electromagnetic interferenc

Pagina 11

11 Rack installation • Reserve at least 1 m (3.28 ft) of clearance between the rack and walls or other devices. • The equipment room is at least 3

Pagina 12 - NSQ1GP4U0

Copyright © 2007-2013, Hangzhou H3C Technologies Co., Ltd. and its licensors All rights reserved No part of this manual may be reproduced or transmi

Pagina 13

12 Cage nuts (user-supplied) ESD-preventive wrist strap (user-supplied) Cable tie (user-supplied) Insulation sheath (user-supplied) Ring termi

Pagina 14 - Preparing for installation

13 Item Requirements Result EMI prevention • Take effective measures to protect the power system from the power grid system. • Separate the protec

Pagina 15 - Temperature and humidity

14 Installing the firewall Figure 13 Firewall installation flow Confirming installation preparations Before you install the firewall, verify that:

Pagina 16 - Cooling

15 • The firewall is ready for installation and has been carried to a place near the installation site and convenient for moving. Unpacking the fire

Pagina 17 - ESD prevention

16 Figure 15 Marking the positions of the cage nuts 2. As shown in Figure 16, insert one edge of a cage nut into the hole, and compress the other

Pagina 18 - Lightning protection

17 Figure 18 Attaching the rear mounting brackets to the rack 4. Align the screw holes in one mounting bracket with the screw holes in the side pa

Pagina 19 - Accessories

18 Figure 21 Sliding the firewall into the rack 7. Attach the firewall horizontally by fastening the mounting brackets to the rack with appropriat

Pagina 20

19 Installing an F1000-S-EI in the rack To install the firewall in the rack: 1. As shown in Figure 23, mark the positions of the cage nuts on the fr

Pagina 21

20 Figure 25 Cage nuts installed 3. Align the screw holes in one mounting bracket with the screw holes in the side panel of the chassis, and use s

Pagina 22 - Installing the firewall

21 3. Secure the metal part of the cable to the ring terminal with a crimper, cover the joint with the insulation covering, and heat the insulation

Pagina 23 - Unpacking the firewall

Preface The H3C SecPath F1000-E/F1000-S-EI Firewalls Installation Guide includes eight chapters, which describe the product overview, preparing for i

Pagina 24

22 Figure 27 Connecting the grounding cable to the grounding hole of firewall (F1000-E) NOTE: • The resistance reading should be smaller than 5

Pagina 25

23 Figure 28 Inserting the CF card into the slot Connecting interface cables Connecting a copper Ethernet port You can use category-5 or above twis

Pagina 26

24 To connect a fiber port to a peer device through optical fibers (F1000-E): 1. Remove the dust plug from the fiber port. 2. Remove the dust cover

Pagina 27

25 Figure 30 Connecting an AC power cord to the firewall Verifying the installation To ensure normal operation of the firewall, verify the followin

Pagina 28 - Grounding the firewall

26 Installing FRUs You can install an interface module, a lightning protector for a network port, and a power strip with lightning protection on an F

Pagina 29

27 Connecting to an RPS power cord The RPS power cord only connects to the F1000-E firewall. To connect to an RPS power cord: 1. Make sure the power

Pagina 30 - Installing a CF card

28 Installing a lightning protector for a network port The lightning protector for a network port is only applicable to a copper Ethernet port. If

Pagina 31 - Connecting interface cables

29 Figure 35 Installing a lightning protector (1) Outdoor network cable (2) Grounding wire (3) Lightning protector for a network port (4) Cable con

Pagina 32 - Connecting an AC power cord

30 Figure 36 Power strip with lightning protection (1) Operating LED (green) On means the circuit is operating properly. Off means the circuit is d

Pagina 33 - Verifying the installation

31 Logging in and performing basic configurations The first time you access the firewall, you can log in to the CLI through the console port or log i

Pagina 34 - Installing FRUs

Convention Description &<1-n> The argument or keyword and argument combination before the ampersand (&) sign can be entered 1 to n times

Pagina 35

32 Figure 37 Connecting the terminal to the firewall IMPORTANT: • Identify the mark on the console port and make sure you are connecting to the c

Pagina 36 - Installation procedure

33 3. Select the serial port used to connect to the firewall and click OK. Figure 39 Selecting the serial port 4. Configure serial port propertie

Pagina 37 - Installation precautions

34 Table 6 Serial port properties Property Value Bits per second 9600 bps (the default) Data bits 8 Parity None Stop bits 1 Flow control None To

Pagina 38

35 Figure 42 Selecting the emulation type 7. Select VT100 or Auto detect for Emulation and click OK. Powering on the firewall Before powering on t

Pagina 39

36 3. For a console login, the boot information on the terminal shows that the firewall is starting up normally. For more information, see "Ver

Pagina 40

37 ... System is starting... ... User interface con0 is available. P

Pagina 41

38 2. Assign the PC an IP address in the network segment 192.168.0.0/24 (except for 192.168.0.1), for example, 192.168.0.2. 3. Launch a Web browser

Pagina 42

39 The syntax of commands and the Web interface vary with software versions. Performing basic configurations at the CLI Step Command Remarks 1. Ent

Pagina 43 - Powering on the firewall

40 Figure 44 Basic configuration wizard—1/6 Configuring the system name and user password 1. Click Next on the first basic configuration page to e

Pagina 44

41 Table 8 Configuration items Item Description Sysname Set the system name. The default system name is H3C. Modify Current User Password Specify wh

Pagina 45

About the H3C SecPath F1000-E/F1000-S-EI documentation set The H3C SecPath F1000-E/F1000-S-EI documentation set includes: Category Documents Purposes

Pagina 46

42 Item Description HTTP Specify whether to enable the HTTP service on the firewall. To enable the HTTP service on the firewall, select the Enable

Pagina 47

43 2. Click the link for an interface to perform IP address configuration as described in Table 10. Table 10 Configuration items Item Description IP

Pagina 48

44 Item Description Dynamic NAT Specify whether to enable dynamic NAT on the interface. If dynamic NAT is enabled, the IP address of the interface wi

Pagina 49 - Configuring services

45 Figure 49 Basic configuration wizard—6/6 2. To modify your configuration, click Back to go back to the previous page. 3. To save the current

Pagina 50

46 Replacement procedures Precautions • Always wear an ESD-preventive wrist strap or ESD-preventive gloves when servicing the firewall. • When remo

Pagina 51 - Configuring NAT

47 Figure 51 Removing an interface module 4. Install a new interface module. For the installation procedures, see the chapter "Installing an

Pagina 52

48 Figure 52 Removing a CF card 5. Install a new CF card. For the installation procedures, see the chapter "Installing a CF card." Repla

Pagina 53

49 4. Put the dust plug on the removed module, and put the removed module into its original shipping materials. 5. Install a new transceiver module

Pagina 54 - Replacement procedures

50 Hardware management and maintenance This chapter describes how to display hardware information for the firewall, verify and diagnose transceiver m

Pagina 55 - Replacing a CF card

51 <Sysname> display diagnostic-information Save or display diagnostic information (Y=save, N=display)? [Y/N]:y Please input the f

Pagina 56

i Contents Product overview ··························································································································

Pagina 57

52 RDS 0% 0/ 65ca IKE 0% 0/ 20ef5

Pagina 58

53 Displaying the electrical label data Electrical label data is also called permanent configuration data or archive information, including name of t

Pagina 59

54 Field Description 1% in last 5 minutes After a boot, the system calculates and records the average CPU usage rate every five minutes. This field d

Pagina 60

55 Fan 1 State: Normal Table 16 Command output Field Description Fan 1 Number of fan. State Fan status: • Normal—The fan is operating pro

Pagina 61

56 Verifying and diagnosing transceiver modules The commonly used transceiver module is as follows: Transceiver type Application scenarios Whether

Pagina 62

57 Step Command Remarks 1. Enter system view. system-view N/A 2. Configure the exception handling method for the system. system-failure { maintain

Pagina 63

58 Troubleshooting The barcode stuck on the firewall chassis contains information about production and servicing. Before you return a faulty firewall

Pagina 64

59 No display on the configuration terminal Symptom After the firewall is powered on, the configuration terminal does not display anything. Solution

Pagina 65 - Rebooting your firewall

60 2. Verify that the working environment of the firewall is well ventilated. 3. If the temperature inside the firewall exceeds 50°C (122°F), the f

Pagina 66 - Troubleshooting

61 Appendix A Technical specifications Dimensions and weight Table 19 Dimensions and weight Item Description F1000-E F1000-S-EI Dimensions (H × W × D

Pagina 67

ii Installing FRUs ···································································································································

Pagina 68 - Solution

62 Power consumption Table 22 Power consumption Item Description F1000-E F1000-S-EI Power consumption 64 W to 110 W 30 W to 46 W Fixed interfaces F

Pagina 69 - Power input

63 Table 24 Console port specifications Item Description Connector type RJ-45 Interface standard RS-232 Baud rate 9600 bps (default) to 115200 bps Ma

Pagina 70 - Fixed interfaces

64 Item Description Transmission distance 100 m (328.08 ft) Rate and negotiation mode 10 Mbps (autosensing) Half-/full-duplex 100 Mbps (autosensing)

Pagina 71 - Combo interfaces

65 Interface modules (optional) 4GBE/8GBE Table 28 4GBE/8GBE specifications Item Description Connector type RJ-45 Number of interfaces 4GBE: 4 8GBE:

Pagina 72 - Ethernet fiber ports

66 Item Description Hot swapping Supported Optical transmit power Type Short-haul multimode Medium-haul single-mode Long-haul single-mode Long-haul

Pagina 73 - Interface modules (optional)

67 Item Description Receiving sensitivity –7.5 dBm –10.3 dBm –11.3 dBm Central wavelength 850 nm 1310 nm 1550 nm Maximum transmission distance 3

Pagina 74

68 Item Description Frame format Ethernet_II Ethernet_SNAP Interface rate 1000 Mbps in full duplex mode Hot swapping Supported Optical transmit pow

Pagina 75

69 Power strip with lightning protection (optional) If part of the AC power line is routed outdoors, use a power strip with lightning protection to c

Pagina 76 - RPS (optional)

70 Appendix B LEDs Panel LEDs F1000-E panel LEDs Figure 54 F1000-E front panel LEDs Table 34 LED description LED Status Description (green) Off N

Pagina 77

71 LED Status Description (green) Off No host is connected to the device-mode USB interface. On A host is connected to the device-mode USB interf

Pagina 78 - Appendix B LEDs

iii Appendix A Technical specifications ··············································································································

Pagina 79 - F1000-S-EI panel LEDs

72 LED Status Description (green) Off No CF card is present or the CF card is not recognizable. On A CF card is in position and has passed the P

Pagina 80 - Interface module LEDs

73 4GBP Figure 58 4GBP status LED Table 38 LED description LED Status Description (yellow/green) Off No link is present on the port. Steady gre

Pagina 81

74 NSQ1GT2UA0 Figure 60 NSQ1GT2UA0 LEDs Table 40 LED description LED Status Description (green) Off No link is present. On A link is present.

Pagina 82

75 Appendix C Arranging slots and numbering interfaces Arranging slots The F1000-E/F1000-S-EI supports console, fiber, and copper ports. This chapter

Pagina 83 - Examples

76 { GigabitEthernet 0/0 { GigabitEthernet 0/1 { GigabitEthernet 0/2 { GigabitEthernet 0/3 2. If both slot 1 and slot 2 of the F1000-E are insta

Pagina 84

77 Appendix D Cables This chapter describes cables used for connecting network ports. Table 42 Cable description Cable Port type Application Ethernet

Pagina 85 - Appendix D Cables

78 Figure 64 RJ-45 connector pinout diagram NOTE: The RJ-45 Ethernet interfaces use category 5 or higher Ethernet twisted pair cables for connect

Pagina 86

79 Figure 66 Crossover cable Select an Ethernet twisted pair cable according to the RJ-45 Ethernet port type on your device. An RJ-45 Ethernet inte

Pagina 87

80 Pin 10Base-T/100Base-TX 1000Base-T Signal Function Signal Function 5 Reserved N/A BIDD- Bi-directional data cable D- 6 Tx- Send data BIDA-

Pagina 88 - Optical fiber

81 Table 46 Allowed maximum tensile force and crush load Period of force Tensile load (N) Crush load (N/mm) Short period 150 500 Long term 80 10

Pagina 89 - Long term 80 100

1 Product overview The H3C SecPath F1000-E Firewall and H3C SecPath F1000-S-EI Firewall are new-generation gigabit firewalls developed for medium- and

Pagina 90 - General cabling requirements

82 Appendix E Cabling recommendations When a firewall is mounted in a 19-inch standard rack, the interface cables are routed through the cable manage

Pagina 91

83 Figure 68 Correct and incorrect cable binding • Route different types of cables (for example, power cables and signal cables) separately. If th

Pagina 92

84 Figure 70 Binding cables where they must be bent • Route, bind, and attach excess cables for easy, safe maintenance activities and proper opera

Pagina 93 - Cabling examples

85 Cable bundle diameter (mm) Space between bundles (mm) 30 200 to 300 • Do not tie cables or bundles in a knot. • The metal parts of the crimped

Pagina 94

86 Index A C D E F G I L M N O P R S T U V A Accessories,11 Arranging slots,75 C Cable management requirements,82 Cabling examples,85 Checklist befo

Pagina 95

87 Troubleshooting password loss,59 Troubleshooting power supply system failures,58 Troubleshooting system exceptions,56 Troubleshooting the interfac

Comentarios a estos manuales