22
Figure 27 Connecting the grounding cable to the grounding hole of firewall (F1000-E)
NOTE:
The resistance reading should be smaller than 5 ohms between firewall chassis and the ground.
To guarantee the grounding effect, use the grounding cable provided with the firewall to connect to
the grounding strip in the equipment room as long as possible.
Installing a CF card
IMPORTANT:
Before you boot the firewall, make sure the CF card with correct system software image has been
correctly installed into the CF card slot. Otherwise, the firewall cannot be booted.
To install a CF card:
1. Push the CF card eject button all the way into the slot and make sure the button does not project
from the panel.
2. Insert the CF card into the slot following the direction shown in Figure 28, and
make sure it does
not project from the slot.