13
Item Re
q
uirements
Result
EMI prevention
Take effective measures to protect the power system
from the power grid system.
Separate the protection ground of the firewall from
the grounding device or lightning protection
grounding device as far as possible.
Keep the firewall far away from high-power radio
launchers, radars, and equipment with high
frequency or high current.
Use electromagnetic shielding when necessary.
Lightning
protection
The grounding cable of the chassis is well grounded.
The grounding terminal of the AC power receptacle
is well grounded.
A power lightning arrester is installed. (Optional)
Electricity safety
Equip an uninterrupted power supply (UPS).
In case of emergency during operation, switch off
the external power switch.
Workbench-mounti
ng requirements
The workbench is sturdy and well grounded.
Rack-mounting
requirements
Install the firewall in an open rack if possible. If you
install the firewall in a closed cabinet, make sure the
cabinet is equipped with a good ventilation system.
The rack is sturdy enough to support the weight of
the firewall and installation accessories.
The size of the rack is appropriate for the firewall.
The front and rear of the rack are at least 0.8 m
(2.62 ft) away from walls or other devices.
Tools
Installation accessories supplied with the firewall
User-supplied tools
Reference
Documents shipped with the firewall
Online documents